Buchi Logo
  • Fields of Activities
    • Evaporation Solutions
      • Rotavapor® Systems
      • Rotavapor® R-210/R-215
      • Rotavapor® R II
      • Rotavapor® R-3
      • Vacuum Solutions
      • Vacuum Pump V-700
      • Vacuum Pump V-710
      • Vacuum Controller V-850/V-855
      • Vacuum Modules EasyVac
      • Vacuum Modules LabVac
      • Recirculation Chiller
      • Glass Oven B-585 Kugelrohr
      • Glass Oven B-585 Drying
    • Industrial Evaporation
      • Rotavapor R-220 SE
      • Rotavapor R-220 EX
      • Rotavapor R-250
      • Rotavapor R-250 EX
      • Chiller for R-220 SE
    • Spray Drying & Encapsulation
      • Nano Spray Dryer B-90
      • Mini Spray Dryer B-290
      • Inert Loop B-295
      • Dehumidifier B-296
      • Encapsulator B-390 / B-395 Pro
    • Melting Point
      • Melting Point M-560
      • Melting Point M-565
      • Sample Loader M-569
    • Parallel Evaporation
      • Multivapor P-6/P-12
      • Syncore Polyvap
      • Syncore Analyst
      • SPE and Evaporation
    • Flash Chromatography
      • Manual Controlled
      • Computer Controlled
      • Applications
      • Systems
    • Extraction Solutions
      • Classical Extraction
      • Pressurized Solvent Extraction
      • Sample Preparation
    • Kjeldahl Solutions
      • Digestion
      • Distillation
      • Kjeldahl Tablets
    • NIRSolutions
      • NIRFlex
      • NIRMaster
      • NIRWare
      • NIRCal
      • Online
      • NIR Applications
  • Applications
    • Search
    • Parallel Evaporation
    • NIR Applications
    • Spray Dryer Application Finder
    • Flash Chromatography
    • Kjeldahl
      • Application Notes Order Area
    • Extraction
      • Application Notes Order Area
    • Melting Point
    • best@buchi
    • Literature
    • Application Support
  • Service & Support
    • Technical Support
    • Maintenance Contracts
    • Training@buchi
    • Downloads (Manuals etc)
    • Find your local Service Center
    • Individual Consulting
    • Contact
    • Two-Year Warranty Registration
  • About BUCHI
    • Company Profile
    • News
    • Events
    • Worldwide
      • Africa
      • Asia
      • Europe
      • Latin America
      • Middle East
      • North America
      • Oceania
      • All other countries
    • Affiliated Companies
    • Careers
    • Company & History Movies
    • Management
    • Find us
    • Awards
  • Customer Statements
    • Case Studies
    • Interviews
      • Interview details
    • Videos Customer Statements

Your basket

Home > Fields of Activities > Kjeldahl Solutions > Products > Distillation > Distillation Unit K-350 > Features

Distillation Unit K-350

Easy-to-use Distillation Unit for classical Kjeldahl applications






Get the Facts

 
  • Features
  • Applications
  • Accessories
  • Spare Parts
  • Specifications

Safety features


With its numerous safety features, the K-350 provides maximum user protection and helps to prevent the loss of samples:

  • Integrated time controlled pump for adding reagent safely into the sample tube
  • Protective door
  • Protective door sensor
  • Sample tube sensor
  • Service door sensor
  • Drip tray
  • Cooling water ON/OFF automatics

 

Integrated timer


The integrated timer enables to set the required distillation time. It can be set in a range of 1 second to 99 minutes and 59 seconds. A reagent dosage button enables to add one reagent during distillation.

 

Steam generator


The maintenance-free, high-performance steam generator switches to stand-by mode when unattended for more than 30 minutes.

  • > 30 ml of condensate per minute
  • Short distillation time
  • High recovery rate of > 99.4 %
  • Short preheating time

Easy maintenance


The working parts are easily accessible from the front thanks to the service door.

Two splash protection variants


The design of the splash protector is crucial for reproducible protein and nitrogen determination.

BUCHI offers two variants:
The proven glass variant and the new variant made of glass-fibre reinforced polypropylene.

With the glass variant optimal visual monitoring of the entire process is possible through the transparent distillation area.

The polypropylene variant is particulary durable and is ideal wherever a large number of samples are processed.

  • Top of page
  • Privacy
  • Sitemap
  • Partnernet
  • Terms
  • Webmaster
  • Print
  • © 2012 BÜCHI Labortechnik AG
BÜCHI Labortechnik AG Logo BÜCHI Labortechnik AG
Meierseggstrasse 40
Postfach
CH-9230 Flawil 1
Switzerland

www.buchi.com
buchi@buchi.com
Tel: +41 71 394 63 63
Fax: +41 71 394 64 64

© 2008 BÜCHI Labortechnik AG    
last modified: 07 March 2011
  • Global Site
  • Worldwide

Contact BUCHI

Contact BUCHI
  • Order a print brochure
Operation manuals of discontinued products

Product information

  • Brochures Distillation Unit K350/355 (pdf, 492.01k)
  • Original Glass-Ware (pdf, 3.4Mb)
  • Products & Solutions EN (pdf, 1.33Mb)
  • Kjeldahl Solutions (pdf, 1.16Mb)
  • Kjeldahl DIN ISO Methods (pdf, 104.45k)
  • Kjeldahl AOAC Methods (pdf, 90.08k)
  • All Downloads

Buchi community *

  • Operation Manual Distillation Unit K-350 (pdf, 1.14Mb)
  • Manuel d'instructions Unité de distillation K-350 (pdf, 1.15Mb)
  • Manual de instrucciones Unidad de Destilación K-350 (pdf, 1.15Mb)
  • Istruzioni per l'uso Unità di distillazione K-350 (pdf, 1.17Mb)
  • Betriebsanleitung Destillationsgerät K-350 (pdf, 1.15Mb)

* free registration required

Complementary products

  • Sample Preparation

Your account

Login


Forgot your password?Newsletter ArchiveSubscribe to our Newsletter